The reconstruction is based on the classical filtered backprojection technique. Filtered back projection is an analytic reconstruction algorithm designed to overcome the limitations of conventional back projection. With fbp, ct slices are reconstructed from projection data sinograms by applying a highpass filter followed by a backward projection step fig. Ct image reconstruction tomoshop new generation ct. Comparison of image quality from filtered back projection. Set of functions performing ct reconstruction tasks like a radon transformation, a simple backprojection, a filtered backprojection using a convolution in the spatial domain, a filtered backprojection using a 2d fourier transformation, and a filtered back projection using the central slice theorem. Computationally intensive tasks are gpu accelarated, achieving unprecedented performance. The infamous shepplogan phantom reconstructed from tomographic data sinogram using the classical filtered backprojection algorithm. Backprojection onto reconstruction plane for example, after only three projections, the lines would intersect to yield a. Hounsfield unit hu and tissue mineral density calibration procedures were performed in ctan software ct analyzer, v.
Since then, this technique has caused a true hype in the. Emphysema quantification using ultralowdose ct with. By using iterative reconstruction algorithms in ct the image noise can be reduced comparing to filtered back projection fbp if the same dose is applicated. Filtering is used to minimize streaks on the image that result from back projection smooth imagereduce artifacts. This platform is a scalable software providing both basic image reconstruction features for standard users and advanced tools for specialists in the reconstruction field, to develop, incorporate and assess their own methods in image. Reconstruction of image from simple back projection file. Reconstruct a complete 3d ct model that includes time and motion, creating a truly dynamic volumetric dataset. Filtered back projection fbp is a classical method for image reconstruction from sinogram ct data. Ct reconstruction package file exchange matlab central. To compare organ specific radiation dose and image quality in kidney stone patients scanned with standard ct reconstructed with filtered back projection fbpct to those scanned with low dose ct reconstructed with iterative techniques irct.
Illustration of recovering an object from its xray tomography data also known as sinogram. Pgqquality management slideshare uses cookies to improve functionality and performance, and to provide you with relevant advertising. However, in order to evaluate iterative reconstruction software. It was, up until recently the primary method in crosssectional imaging reconstruction. Filtered back projection radiology reference article. A conebeam ct reconstruction application is provided which implements filtered backprojection using the feldkamp, davis, and kress fdk algorithm. Ctimage processing and reconstruction flashcards quizlet. In order to understand ct reconstruction, we first need to understand how the computed tomography scanner works. For back projection, you calculate the histogram model of a feature and then use it to find this feature in an image. Tomographic reconstruction by filtered backprojection. The kernel affects the appearance of image structures by sharpening the image. Use results to constrain earthquake dynamics coherence between data and synthetics finiteslip inversions backfigure from chen ji projection. Furthermore, this article presents a comprehensive background study on image reconstruction using filtered back projection fbp approaches to develop the ct scanner software.
Castor is an opensource multiplatform project for 4d emission pet and spect and transmission ct tomographic reconstruction. The purpose of this study was to compare the image noisereducing abilities of iterative model reconstruction imr with those of traditional filtered back projection fbp and statistical iterative reconstruction ir in abdominal computed tomography ct images. Comparison of iterative and filtered back projection image reconstruction. Start studying ctimage processing and reconstruction. Filtered back projection fbp algorithms are suited for applications where an image needs to be reconstructed accurately and in near realtime. In fact, it took until 2009 for the first iterative reconstruction algorithms to come commercially available and replace conventional filtered back projection. The kernel, also known as a convolution algorithm, refers to the process used to modify the frequency contents of projection data prior to back projection during image reconstruction in a ct scanner 1. Alexander katsevich, made a revolutionary breakthrough in ct imaging by developing the first fast and exact 3d image.
Filtered back projection vs adaptive statistical iterative. Iterative reconstruction equal to filtered back projection. Image reconstruction for ct scanner by using filtered back. Since the early 1970s, filtered back projection has been used for ct image reconstruction. The advantage of iterative ct reconstruction method is reconstruction results with high image quality can be obtained even with few projected imagesraw data. You can see what any given projection looks like in the simulator above.
Evaluation of heavily calcified vessels with coronary ct angiography. Download tirius tomographic image reconstruction for free. Iterative image reconstruction techniques resulted in ctbased cardiovascular risk categorization that is similar to that obtained with traditional filtered back projection reconstruction, although risk reclassification occurred in a small subset software library which was the result of a european union funded collaboration between 6 different partners. Evaluation of heavily calcified vessels with coronary ct. Comparison of iterative model reconstruction versus. Over a oneyear study period, adult kidney stone patients were retrospectively netted to capture the. The evolution of image reconstruction for ctfrom filtered. Analytic reconstruction filtered backprojection, iterative reconstruction sart, sirt, ossart image filtering used as regularization steps within the iterative reconstruction process. In recent years, iterative ct reconstruction method is drawing attention as a new ct reconstruction against backprojection ct reconstruction method. Chest computed tomography using iterative reconstruction vs filtered back projection. This process corrects the image by reducing blurring 1.
Reconstruction program by matlab based on gui matlab graphical user interface in this program load the initial data in. The first ct scanners in the early 1970s already used iterative reconstruction algorithms. Learn vocabulary, terms, and more with flashcards, games, and other study tools. The reconstruction algorithms used was the back projection bp and filtered back projection. Sign up matlab simulation for computed tomography image reconstruction using filtered back projection. Fully 3dimensional osem spect and pet iterative reconstructions can be obtained within a. Spiral acquisition and reconstruction with a digital flatpanel detector. Fbp is computationally efficient but produces lower quality reconstructions than more sophisticated iterative methods, particularly when the number of views is lower than the number required by the nyquist rate. Implementation of iterative reconstruction offers the ability to minimize radiation exposure while preserving and, in some cases, improving image quality.
Iterative image reconstruction techniques for ct coronary. On the other hand, adequate image quality of fbp can be reached with lower dose using adaptive statistical iterative reconstruction asir by equalizing. They reconstructed raw ct data using filtered back projection and 3 levels of iterative reconstruction. Currently, ct scans for the measurement of nodule size and growth, at baseline and on followup, use the conventional filtered back projection fbp algorithm for image reconstruction. Radiation exposure from multidetector computed tomography ct has become a pressing public health concern in both lay and medical publications. With the fast progress in ct technology, fbpbased algorithms got improved and extended to keep up with hardware progress, such as feldkamp et als 1984 solution for reconstruction of data.
Involves filtered back projection, resulting in a digital matrix, which can be postprocessed for additional image analysis. Back projection is a way of recording how well the pixels of a given image fit the distribution of pixels in a histogram model. Tvminimization by gradient descent, softthreshold filtering. Lambertbeers law and the radon transform 2 2 reconstruction.
Computed tomography the evolution of image reconstruction for ctfrom filtered back projection to artificial intelligence martin j. For the first time, a reconstruction technique based on filtered backprojection fbp using curved 3d backprojection lines is applied to 2d coherent. The volume ct dose index was significantly reduced in studies reconstructed with iterative model reconstruction compared with filtered backprojection, mean, 24. It utilizes simultaneous equations of ray sums taken at differing angles of a sine wave to compute the. Processing large ct data files on gpus has been shown to be effective. Filtered backprojection reconstruction technique for. Kernel image reconstruction for ct radiology reference. Another concept that is useful to use when considering ct reconstruction is the sinogram, which is simply the 2d array of data containing the. Deep back projection for sparseview ct reconstruction. Iterative reconstruction 101 imaging technology news. Projection, backprojection and core iterative reconstruction routines are highly optimised. Approximately 4500 images per sample were reconstructed from xray projections using the backprojection reconstruction algorithm in nrecon software skyscan, v. Many studies have shown that substantial dose savings can be achieved in ct when ir is used 2.
Input images in either raw, pfm, or hnd format are read, filtered, and backprojected into a userdefined volume geometry. Ring reduction compensates for the irregular response of the detector pixels during a ct scan. It is being replaced, however, by iterative reconstruction ir, which is becoming widely used to decrease the radiation dose in ct. Image quality of lowdose ct examinations in 80 patients. Image quality analysis the reconstructed cta images were transferred to workstations with a commercial cardiac ct software package for image. You may receive emails, depending on your notification preferences. The basics for understanding what is iterative reconstruction.
964 1280 1151 610 1295 1270 1353 742 849 868 346 723 786 818 307 1487 1525 1458 753 1067 1255 1586 1057 831 131 981 1542 1074 591 714 1204 634 209 54 1033 107 1003 1313 191